RF JUMPER CABLE [DINMRA-DINMRA]

RF Jumper Cable Coax, 1/2″, High Flex, Low Loss, DIN-Male RA To DIN-Male RA, 50 ohms

    SKU: 0211-1314

•  Product Name: 1/2” RF Jumper Cable
•  Connector Type: DIN-Male RA To DIN-Male RA
•  Compliance Standards: IEC60169, VG95250, EN122190, GJB681-89, GJB360A-96

RF COAXIAL CONNECTOR:

  Material & Planting:   
•   Inner Conductor: Brass, plated with silver.
Plating thickness: ≥0.003mm
•   Insulation Dielectric: PTFE
•   Outer Conductor: Brass, plated with ternary alloy.
Plating thickness: ≥0.002mm
  Electrical & Mechanical Feature:
•   Characteristics impedance: 50Ω
•   Frequency range: DC-3GHz
•   Dielectric strength: ≥2500V
•   Contact resistance: Inner conductor: ≤1.0mΩ,
Outer conductor: ≤0.4mΩ
•   Insulator resistance: ≥5000MΩ (500V DC)
•   VSWR: ≤1.15 (DC-3GHz)
•   PIM (im3): ≤-160dBc@2x43dBm
•   Connector durability: ≥500 cycles

RF COAXIAL CABLE: 1/2” HF CABLE

  Material:
•   Inner Conductor: Aluminium wire covered with copper (φ3.60mm)
•   Insulation Dielectric: PTFE
•   Outer Conductor: Brass, plated with ternary alloy
Plating thickness ≥0.002mm
  Feature:
•   Characteristics impedance: 50Ω
•   Frequency range: DC-3GHz
•   Dielectric strength: ≥2500V
•   Contact resistance: Inner conductor≤1.0mΩ
Outer conductor≤0.4mΩ
•   Insulator resistance: ≥5000MΩ (500V DC)
•   VSWR: ≤1.15 (DC-3GHz)
•   PIM (im3): ≤-160dBc@2x43dBm
•   Connector durability: ≥500 cycles

JUMPER CABLE:

  Cable Components Size: 
•  Total length of cable assemblies: 1m – 5m
  Environmental Features:
•  Waterproof: IP68
•  Operation temperature range: -40℃ to +85℃
•  Storage temperature range: -70℃ to +85℃
  Electrical Feature:
•  Frequency Band: 800-2700MHz
•  Characteristics Impedance: DC-3GHz
•  Operating Voltage: ≥2500V
•  VSWR: Inner conductor≤1.0mΩ, Outer conductor≤0.4mΩ
•  Insulation voltage: ≥5000MΩ (500V DC)
•  Insulation resistance: ≤1.15 (DC-3GHz)
•  PIM3: ≤-160dBc@2x43dBm
  Insertion Loss:
  Frequency 1m 2m 3m 5m
•  890-960MHz ≤0.15dB ≤0.26dB ≤0.36dB ≤0.54dB
•  1710-1880MHz ≤0.20dB ≤0.36dB ≤0.52dB ≤0.80dB
•  1920-2200MHz ≤0.26dB ≤0.42dB ≤0.58dB ≤0.92dB
•  2500-2690MHz ≤0.30dB ≤0.50dB ≤0.70dB ≤1.02dB
•  5800-5900MHz ≤0.32dB ≤0.64dB ≤0.96dB ≤1.6dB

***

•  Mechanical Shock Test Method: MIL-STD-202, Method 213, Test Condition I
•  Moisture Resistance Test Method: MIL-STD-202F, Method 106F
•  Thermal Shock Test Method: MIL-STD-202F, Method 107G,
Test Condition A-1